Wiring for extremely wet conditions
Armoured cables with two rubber-insulated conductors in a flexible
metal sheath were used as early as 1906, and were considered at the time
a better method than open knob-and-tube wiring, although much more
expensive.
The first polymer-insulated
cables
for building wiring were introduced in 1922. These were two or more
solid copper electrical wires with rubber insulation, plus woven cotton
cloth over each conductor for protection of the insulation, with an
overall woven jacket, usually impregnated with tar as a protection from
moisture. Waxed paper was used as a filler and separator.
Over time, rubber-insulated cables become brittle because of exposure
to atmospheric oxygen, so they must be handled with care, and are
usually replaced during renovations. When switches, outlets or light
fixtures are replaced, the mere act of tightening connections may cause
hardened insulation to flake off the conductors. Rubber insulation
further inside the cable often is in better condition than the
insulation exposed at connections, due to reduced exposure to oxygen.
Rubber insulation was hard to strip from bare copper, so copper was
tinned, causing slightly more electrical resistance. Rubber insulation
is no longer used for permanent wiring installations, but may still be
used for replaceable temporary cables where flexibility is important,
such as electrical
extension cords.
About 1950,
PVC
insulation and jackets were introduced, especially for residential
wiring. About the same time, single conductors with a thinner PVC
insulation and a thin nylon jacket (e.g. US Type THN, THHN, etc.) became
common.
Diagram of a simple electrical cable with three insulated conductors
The simplest form of cable has two insulated conductors twisted
together to form a unit; such unjacketed cables with two or three
conductors are used for low-voltage signal and control applications such
as doorbell wiring. In North American practice, an overhead cable from a
transformer on a power pole to a residential electrical service
consists of three twisted (triplexed) wires, often with one being a bare
wire made of copper (protective earth/ground) and the other two being
insulated for the line voltage (hot/line wire and neutral wire). For
additional safety, the ground wire may be formed into a stranded
co-axial layer completely surrounding the phase conductors, so that the
outmost conductor is grounded.
Copper conductors
Electrical devices often contain copper conductors because of their multiple beneficial properties, including their high
electrical conductivity,
tensile strength,
ductility,
creep resistance,
corrosion resistance,
thermal conductivity,
coefficient of thermal expansion,
solderability, resistance to
electrical overloads, compatibility with
electrical insulators, and ease of installation.
Despite competition from other materials, copper remains the preferred
electrical conductor in nearly all categories of electrical wiring.
[8][9] For example, copper is used to conduct electricity in high, medium and low
voltage power networks, including
power generation,
power transmission,
power distribution,
telecommunications,
electronics circuitry,
data processing,
instrumentation,
appliances, entertainment systems,
motors,
transformers, heavy
industrial machinery, and countless other types of
electrical equipment.
[10]
Aluminium conductors
Terminal blocks for joining aluminium and copper conductors. The terminal blocks may be mounted on a
DIN rail.
Aluminium wire
was common in North American residential wiring from the late 1960s to
mid-1970s due to the rising cost of copper. Because of its greater
resistivity, aluminium wiring requires larger conductors than copper. For instance, instead of 14 AWG (
American wire gauge)
for most lighting circuits, aluminium wiring would be 12 AWG on a
typical 15 ampere circuit, though local building codes may vary.
Aluminium conductors were originally indiscriminately used with
wiring devices intended for copper conductors. This practice was found
to cause defective connections unless the aluminium was one of a special
alloy, or all devices — breakers, switches, receptacles, splice
connectors,
wire nuts,
etc. — were specially designed for the purpose. These special designs
address problems with junctions between dissimilar metals, oxidation on
metal surfaces, and mechanical effects that occur as different metals
expand at different rates with increases in temperature.
Unlike copper, aluminium has a tendency to
cold-flow
under pressure, so screw clamped connections may get loose over time.
This can be mitigated by using spring-loaded connectors that apply
constant pressure, applying high pressure cold joints in splices and
termination fittings, and torquing the bolted connection.
[further explanation needed]
Also unlike copper, aluminium forms an insulating oxide layer on the
surface. This is sometimes addressed by coating aluminium wires with an
antioxidant paste at joints, or by applying a mechanical termination designed to break through the oxide layer during installation.
Because of improper design and installation, some junctions to wiring
devices would overheat under heavy current load, and cause fires.
Revised standards for wiring devices (such as the
CO/ALR
"copper-aluminium-revised" designation) were developed to reduce these
problems. Nonetheless, aluminium wiring for residential use has acquired
a poor reputation and has fallen out of favour.
Aluminium conductors are still used for bulk power distribution and
large feeder circuits, because they cost less than copper wiring, and
weigh less, especially in the large sizes needed for heavy current
loads. Aluminium conductors must be installed with compatible
connectors.
Modern wiring materials
Modern non-metallic sheathed cables, such as (US and Canadian) Types NMB and NMC, consist of two to four wires covered with
thermoplastic
insulation, plus a bare wire for grounding (bonding), surrounded by a
flexible plastic jacket. Some versions wrap the individual conductors in
paper before the plastic jacket is applied.
Special versions of non-metallic sheathed cables, such as US Type UF,
are designed for direct underground burial (often with separate
mechanical protection) or exterior use where exposure to
ultraviolet radiation
(UV) is a possibility. These cables differ in having a
moisture-resistant construction, lacking paper or other absorbent
fillers, and being formulated for UV resistance.
Rubber-like synthetic polymer insulation is used in industrial cables
and power cables installed underground because of its superior moisture
resistance.
Insulated cables are rated by their allowable operating voltage and their maximum
operating temperature
at the conductor surface. A cable may carry multiple usage ratings for
applications, for example, one rating for dry installations and another
when exposed to moisture or oil.
Generally, single conductor building wire in small sizes is solid
wire, since the wiring is not required to be very flexible. Building
wire conductors larger than 10
AWG (or about 6 mm²) are stranded for flexibility during installation, but are not sufficiently pliable to use as appliance cord.
Cables for industrial, commercial, and apartment buildings may
contain many insulated conductors in an overall jacket, with helical
tape steel or aluminium armour, or steel wire armour, and perhaps as
well an overall PVC or lead jacket for protection from moisture and
physical damage. Cables intended for very flexible service or in marine
applications may be protected by woven bronze wires. Power or
communications cables (e.g., computer networking) that are routed in or
through air-handling spaces (plenums) of office buildings are required
under the model building code to be either encased in metal conduit, or
rated for low flame and smoke production.
Mineral insulated cables at a panel board
For some industrial uses in steel mills and similar hot environments,
no organic material gives satisfactory service. Cables insulated with
compressed
mica flakes are sometimes used. Another form of high-temperature cable is a
mineral insulated cable, with individual conductors placed within a copper tube, and the space filled with
magnesium oxide powder. The whole assembly is drawn down to smaller sizes, thereby compressing the powder. Such cables have a
certified
fire resistance rating, and are more costly than non-fire rated cable.
They have little flexibility and behave more like rigid conduit rather
than flexible cables.
Because multiple conductors bundled in a cable cannot dissipate heat
as easily as single insulated conductors, those circuits are always
rated at a lower "
ampacity".
Tables in electrical safety codes give the maximum allowable current
for a particular size of conductor, for the voltage and temperature
rating at the surface of the conductor for a given physical environment,
including the insulation type and thickness. The allowable current will
be different for wet or dry, for hot (attic) or cool (underground)
locations. In a run of cable through several areas, the most severe area
will determine the appropriate rating of the overall run.
Cables usually are secured by special fittings where they enter
electrical apparatus; this may be a simple screw clamp for jacketed
cables in a dry location, or a polymer-gasketed cable connector that
mechanically engages the armour of an armoured cable and provides a
water-resistant connection. Special cable fittings may be applied to
prevent explosive gases from flowing in the interior of jacketed cables,
where the cable passes through areas where inflammable gases are
present. To prevent loosening of the connections of individual
conductors of a cable, cables must be supported near their entrance to
devices and at regular intervals through their length. In tall
buildings, special designs are required to support the conductors of
vertical runs of cable. Usually, only one cable per fitting is allowed
unless the fitting is otherwise rated.
Special cable constructions and termination techniques are required
for cables installed in ocean-going vessels; in addition to electrical
safety and fire safety, such cables may also be required to be
pressure-resistant where they penetrate bulkheads of a ship. Resistance
to
corrosion caused by
salt water or
salt spray is also required.